Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BJU Int ; 133(5): 539-547, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38097529

RESUMO

OBJECTIVES: To evaluate psychological, social, and financial outcomes amongst individuals undergoing a non-contrast abdominal computed tomography (CT) scan to screen for kidney cancer and other abdominal malignancies alongside the thoracic CT within lung cancer screening. SUBJECTS AND METHODS: The Yorkshire Kidney Screening Trial (YKST) is a feasibility study of adding a non-contrast abdominal CT scan to the thoracic CT within lung cancer screening. A total of 500 participants within the YKST, comprising all who had an abnormal CT scan and a random sample of one-third of those with a normal scan between 14/03/2022 and 24/08/2022 were sent a questionnaire at 3 and 6 months. Outcomes included the Psychological Consequences Questionnaire (PCQ), the short-form of the Spielberger State-Trait Anxiety Inventory, and the EuroQoL five Dimensions five Levels scale (EQ-5D-5L). Data were analysed using regression adjusting for participant age, sex, socioeconomic status, education, baseline quality of life (EQ-5D-5L), and ethnicity. RESULTS: A total of 380 (76%) participants returned questionnaires at 3 months and 328 (66%) at 6 months. There was no difference in any outcomes between participants with a normal scan and those with abnormal scans requiring no further action. Individuals requiring initial further investigations or referral had higher scores on the negative PCQ than those with normal scans at 3 months (standardised mean difference 0.28 sd, 95% confidence interval 0.01-0.54; P = 0.044). The difference was greater in those with anxiety or depression at baseline. No differences were seen at 6 months. CONCLUSION: Screening for kidney cancer and other abdominal malignancies using abdominal CT alongside the thoracic CT within lung cancer screening is unlikely to cause significant lasting psychosocial or financial harm to participants with incidental findings.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/psicologia , Pessoa de Meia-Idade , Idoso , Detecção Precoce de Câncer/psicologia , Estudos de Viabilidade , Qualidade de Vida , Inquéritos e Questionários , Radiografia Torácica , Radiografia Abdominal , Ansiedade , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/psicologia
2.
Urologia ; 90(1): 25-29, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35730798

RESUMO

BACKGROUND: Stone disease is a common complication of horseshoe kidneys (HSK). There are currently limited studies that examine the relationship between HSK anatomy and stone formation. We aim to determine if there is such an association by measuring the isthmus size and renal angulation in both stone and non-stone forming HSK using computed tomography (CT). METHOD: This is a retrospective study performed at a single tertiary centre. Using the radiological information system, all CT reports between 01 January 2010 and 31 December 2015 were searched for the keyword 'horseshoe' on the radiological information system. This produced a list of 285 reports. Each report and image packet of these 285 studies were reviewed to confirm the presence of an HSK and duplicate patients from multiple examinations were highlighted. One hundred and thirty-eight unique HSK patients were obtained and the studies were assessed for the presence or absence of stones. A total of 112 HSK were found; 88 of which contained no stone and 24 with stone. Angle measurements and isthmus size were measured on these kidneys. As axial images are obtained as standard in all cases, these measurements were all obtained in the axial plane. All parameters were measured and recorded manually by one person so as to reduce inter-observer variability. RESULTS: Isthmus size varied widely, measuring from 2 to 39 mm. Right renal angle ranged from 51 to 158°, left 38 to 152°. CONCLUSION: The isthmus size and renal angle measurements were not found to be significant determinants for stone disease in our patient population.


Assuntos
Rim Fundido , Urolitíase , Humanos , Rim Fundido/complicações , Rim Fundido/diagnóstico por imagem , Estudos Retrospectivos , Rim/diagnóstico por imagem , Tomografia Computadorizada por Raios X
3.
BMJ Open ; 12(9): e063018, 2022 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-36127097

RESUMO

INTRODUCTION: Kidney cancer (renal cell cancer (RCC)) is the seventh most common cancer in the UK. As RCC is largely curable if detected at an early stage and most patients have no symptoms, there is international interest in evaluating a screening programme for RCC. The Yorkshire Kidney Screening Trial (YKST) will assess the feasibility of adding non-contrast abdominal CT scanning to screen for RCC and other abdominal pathology within the Yorkshire Lung Screening Trial (YLST), a randomised trial of community-based CT screening for lung cancer. METHODS AND ANALYSIS: In YLST, ever-smokers aged 55-80 years registered with a general practice in Leeds have been randomised to a Lung Health Check assessment, including a thoracic low-dose CT (LDCT) for those at high risk of lung cancer, or routine care. YLST participants randomised to the Lung Health Check arm who attend for the second round of screening at 2 years without a history of RCC or abdominal CT scan within the previous 6 months will be invited to take part in YKST. We anticipate inviting 4700 participants. Those who consent will have an abdominal CT immediately following their YLST thoracic LDCT. A subset of participants and the healthcare workers involved will be invited to take part in a qualitative interview. Primary objectives are to quantify the uptake of the abdominal CT, assess the acceptability of the combined screening approach and pilot the majority of procedures for a subsequent randomised controlled trial of RCC screening within lung cancer screening. ETHICS AND DISSEMINATION: YKST was approved by the North West-Preston Research Ethics Committee (21/NW/0021), and the Health Research Authority on 3 February 2021. Trial results will be disseminated at clinical meetings, in peer-reviewed journals and to policy-makers. Findings will be made available to participants via the study website (www.YKST.org). TRIAL REGISTRATION NUMBERS: NCT05005195 and ISRCTN18055040.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Neoplasias Pulmonares , Detecção Precoce de Câncer/métodos , Estudos de Viabilidade , Humanos , Rim/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Tomografia Computadorizada por Raios X/métodos
4.
Br J Radiol ; 94(1125): 20210475, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34289324

RESUMO

OBJECTIVES: To determine biopsy device failures, causative factors, complications and sample quality of the 16G end-cut Biopince™ and side-notch Bard™ needles. METHODS: All ultrasound-guided non-targeted liver biopsies between 01/01/2016 and 31/12/2018 were included. Operator, device, number of failures, complications and repeat biopsies were recorded. Histopathology samples were reviewed for all cases of needle failure and a group with no failures, and graded "yes/no" for the presence of steatosis, inflammation and fibrosis. The pathology slides from these cases were reviewed to assess biopsy sample quality (length and portal tract number). The failure and no-failure groups were compared in terms of device type/histology, and sample quality was compared between the needle types. RESULTS: 1004 patients were included. 93.8% (n = 942) required one needle pass to obtain a sample and 6.2% (n = 62) required >1 pass due to needle failure. Total of 76 needle failures, more with end-cut than side-notch needles (8.7% vs 2.9%) (p < 0.001). No needle failures resulted in complication. The presence of liver fibrosis was associated with fewer needle failures (p = 0.036). The major complication rate was 0.4% (4/1044). A biopsy with >10 portal tracts was obtained in 90.2% of specimens > 20 mm long, compared with 66% of 16-20 mm biopsies and 21% of <16 mm biopsies. The target of >10 portal tracts was achieved in 10/26 (38.5%) of side-notch biopsies and 64/90 (71.1%) of end-cut biopsies (p = 0.004). CONCLUSION: Ultrasound-guided liver biopsy is safe and sample quality is consistently good when a core >20 mm long is obtained. The end-cut biopsy device generated reliably good quality biopsy samples; however, the needle failure rate was significantly higher than the side-cut needle. ADVANCES IN KNOWLEDGE: Ultrasound-guided liver biopsy specimen quality is consistently good when a core >20 mm long is obtained which can be achieved with a single pass using the 16G BiopinceTM end-cut needle, although the needle failure rate is significantly higher than the 16G Max-Core™ Bard™ side-notch needle.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Fígado/patologia , Ultrassonografia de Intervenção/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Desenho de Equipamento , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
5.
Front Oncol ; 10: 167, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32154169

RESUMO

Objectives: To characterize treatment patterns and survival outcomes for patients with locally advanced or metastatic malignancy of the urothelial tract during a period immediately preceding the widespread use of immune checkpoint inhibitors in the UK. Patients and Methods: We retrospectively examined the electronic case notes of patients attending the Leeds Cancer Center, UK with locally advanced or metastatic urothelial carcinoma, receiving chemotherapy between January 2003 and March 2017. Patient characteristics, treatment patterns, and outcomes were collected. Summary and descriptive statistics were calculated for categorical and continuous variables as appropriate. The Kaplan-Meier method was used to estimate median survival and Cox regression proportional hazards model was used to explore relationships between clinical variables and outcome. Results: Two hundred and sixteen patients made up the study cohort, with a median age of 66 years (range: 35-83) and 72.7% being male. First-line treatment consisted of either a cisplatin- (44%) or carboplatin-based regimen (48%) in the majority of patients. Twenty seven percent of patients received a second-line of treatment (most commonly single-agent paclitaxel) following a first-line platinum containing regimen. Grade 4 neutropenia was observed in 19 and 27% of those treated with a first-line cisplatin- and carboplatin-based regimen, respectively. The median overall survival (mOS) of the study cohort was estimated to be 16.2 months (IQR: 10.6-28.3 months). Receipt by patients of cisplatin-based chemotherapy was associated with a longer mOS and this association persisted when survival analysis was adjusted for age, sex, performance status and presence of distant metastases. Conclusions: This study provides a useful benchmark for outcomes achieved in a real-world setting for patients with locally advanced or metastatic UC treated with chemotherapy in the immediate pre-immunotherapy era.

6.
Urol Ann ; 12(1): 96-100, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32015629

RESUMO

Ureteral stents are routinely used in urological practice for many indications including obstruction of ureter, ureteral stricture, prior to treatment with extracorporeal shock wave lithotripsy, and to promote healing following ureteral injury. Complications reported with ureteric stents include stent migration, stent rupture, encrustation, ureteral perforation, erosion, and fistulation. Knotting of an indwelling ureteral stent is a very rare complication, with fewer than 30 cases reported in the literature. Techniques for managing this complication include using a holmium laser to cut the knot, percutaneous antegrade removal, and gentle traction. We describe the case of a knotted stent and its removal along with a comprehensive literature review.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA